Skip to content

Opportunity overview

Active Federal PPRA / EPADS Official source

Procurement for Air Conditioner

State Life, Swat Zone (State Life Insurance Corporation of Pakistan (SLIC))

Reference: P174552

Closes in 9 days

Tender information

Published
Submission deadline
Procurement method
Request for Quotation
Procuring agency
State Life, Swat Zone (State Life Insurance Corporation of Pakistan (SLIC))
Location
Swat , Khyber Pakhtunkhwa

Tender description

  • Air Conditioner

Technical Specifications

Air Conditioner

Technical Specifications/Requirements:
S.No
__EMPTY
Technical Parameters
__EMPTY_1
Required Specification
Technical Specifications/Requirements:
1
__EMPTY
Tem
__EMPTY_1
2.0 Ton DC Invertor Split Air Co nditioner- Supply, Installation, Testing & Commissioning.
Technical Specifications/Requirements:
2
__EMPTY
Teyp
__EMPTY_1
Wall-Mounted split type full DC Inverter Air Conditioner
Technical Specifications/Requirements:
3
__EMPTY
colloing Capacity
__EMPTY_1
Minimum 2.0 Ton/24000 BTU/hr
Technical Specifications/Requirements:
4
__EMPTY
Compressor
__EMPTY_1
High-efficiency T3 tropicl DC Inverter Compressor
Technical Specifications/Requirements:
5
__EMPTY
Ambient Temperature
__EMPTY_1
Suitable for high ambient temperature up to 50-52C
Technical Specifications/Requirements:
6
__EMPTY
Operation
__EMPTY_1
Heat & Cool
Technical Specifications/Requirements:
7
__EMPTY
Power Supply
__EMPTY_1
220-240V, 50Hz, Single Phase
Technical Specifications/Requirements:
8
__EMPTY
Refrigerant
__EMPTY_1
R-32 or R-410A, as applicable to quoted model
Technical Specifications/Requirements:
9
__EMPTY
Evaporator Coil
__EMPTY_1
100% Copper tubing with suitable anti-corrosion coating
Technical Specifications/Requirements:
10
__EMPTY
Condensor Coil
__EMPTY_1
100% Copper tubing with suitable aniti-corrosion coating
Technical Specifications/Requirements:
11
__EMPTY
Airflow
__EMPTY_1
High-Volume /long-distance air throw suitable for office use
Technical Specifications/Requirements:
12
__EMPTY
Air Swing
__EMPTY_1
Auto swing with adjustable airflow direction
Technical Specifications/Requirements:
13
__EMPTY
Air Filter
__EMPTY_1
Washable/resuable air filter
Technical Specifications/Requirements:
14
__EMPTY
Energy Efficeincy
__EMPTY_1
High-efficency inverter thechnology, minimum applicable NEECA efficency requiremts or higher
Technical Specifications/Requirements:
15
__EMPTY
voltage Protection
__EMPTY_1
Built-in protection against voltage fluctuation, overload, over-current and high/low voltage
Technical Specifications/Requirements:
16
__EMPTY
PCB
__EMPTY_1
Protected/durable PCB duitable for opration uder voltage fluctuations
Technical Specifications/Requirements:
17
__EMPTY
Copper Piping
__EMPTY_1
100% copper refrigerant suction and liquid lines with proper thermal insulation
Technical Specifications/Requirements:
18
__EMPTY
Drainage
__EMPTY_1
Complete condiensate drainge arrangement with suitable quality drain pipe
Technical Specifications/Requirements:
19
__EMPTY
Remote Control
__EMPTY_1
Original wireless remote control with batteries
Technical Specifications/Requirements:
20
__EMPTY
Outdoor Bracket
__EMPTY_1
Heavy duty MS/Steel bracket , properly coated/painted for corrosion protection
Technical Specifications/Requirements:
21
__EMPTY
Installation
__EMPTY_1
Complete installation, testing and commissioning at site
Technical Specifications/Requirements:
22
__EMPTY
Accessories
__EMPTY_1
all requred fittings, insulation, wiring, drain piping, supports, scres and installation accessories included
Technical Specifications/Requirements:
23
__EMPTY
Warranty
__EMPTY_1
Minimum 03 years comprehensive warranty, 08 years compressor warranty and 04 years PCB warranty, or manufactures's higher warranty.
Technical Specifications/Requirements:
24
__EMPTY
Condition
__EMPTY_1
Brand new, unsued and latest available model
Technical Specifications/Requirements:
25
__EMPTY
Technical documents
__EMPTY_1
manufacture's original technical brochaure/data sheet showing quated model and technical specifictions
Technical Specifications/Requirements:
26
__EMPTY
Brand
__EMPTY_1
Any Reputed/established brand or equivalent meeting or exceeding the specifications
Technical Specifications/Requirements:
27
__EMPTY
Testing & Commissioning
__EMPTY_1
Supplier shall ensure complete operational testing and satisfactory commissioning at handover
Technical Specifications/Requirements:
28
__EMPTY
Extra Piping
__EMPTY_1
Additional copper pipe (if required)
__EMPTY
Taxes
__EMPTY_1
All Taxes should be included with transporation and installation cost

Official source

Always confirm dates, documents, and submission instructions on the originating portal.

View original tender on Federal PPRA / EPADS