Construction of Room for Filtration Plant and Drinking Water Area adjacent to AB-22.EFS 79806

Comsat University , Islamabad (Comsats University, Islamabad)

Reference: P178341

Closes in 4 days

Tender information

Published
Submission deadline
Category
Civil construction
Procurement method
Request for Quotation
Procuring agency
Comsat University , Islamabad (Comsats University, Islamabad)
Location
Islamabad , Islamabad Capital Territory

Tender description

  • Construction of Room for Filtration Plant and Drinking Water Area adjacent to AB-22.EFS 79806
  • Excavation for foundations, in all kinds of soil (except conglomeration of gravel and boulders, soft, sandy or disintegrated and hard rock) and back filling the excavated material all-round the trenches including breaking clods, watering, consolidat
  • Providing and laying 4” thick 1:4:8 cement concrete using screened graded crushed stone 1/2" (13mm) and down gauge from approved source and lawrancepur sand as per specifications in foundation, under floor, under walk way including levelling, compact
  • Providing and laying first class solid burnt brick masonry set in CSM (1:6) in straight or curved walls 9” to 18" thick including scaffolding, raking, out joints and curing etc; complete in foundation, as directed by the Engineer Incharge .
  • Providing and laying 1:2:4 cement concrete hollow paving block masonry of 6”x8”x16” thick, set in CSM (1:4) in straight or curved walls including scaffolding, raking, out joints and curing etc; complete in ground floor, as directed by the Engineer In
  • Providing and laying Precast Slab, including Precast Gurder , 3” thick P:C:C (1:2:4) screeding, leveling and curing, etc. complerte as directed by the Engineer Incharge.
  • Providing laying and applying 3mm thick roof grip water proofing PLASTO GRIP RLA-400 Modified bituminous membrane torch applied polymerized containing non-woven polyester coated, on lower side with PP modified bitumen compound with polyethylene film
  • Providing and applying cement sand (1:4) 1/2" thick plaster on internal/external walls and columns etc; in ground floor including making edges, corners and curing etc. as directed by the Engineer Incharge.
  • Providing and fixing of glazed Champagne anodized or powder coated aluminum openable ventilator as per British standard executive model section single glazed 101mmx37mm and 2mm thick including aluminum jali , the cost of fitting, with all accessories
  • Providing and fixing, 12 mm thick glass door including fix glass also including floor machine, matching hardware, door handles, locking arrangements etc, complete as per direction of engineer incharge.
  • Providing and fixing specific thickness full width Prepolished Granite Slab for top of drinking water area wall 3/4" thick for up to 12 Sft size, including grinding, polishing, making nose, cutting, etc complete as per direction of engineer incharge.
  • Providing and fixing, 16 SWG. Stainless Steel Drain Chanel (Tray), Size 1’ width, 6” deep including fixing arrangements, cutting, welding, Grinding, painting, nuts, bolts and washers etc, complete as per Drawing and direction of engineer incharge.
  • Providing and installation of UPVC class-B drainage pipes including cost of all kinds of fittings such as Wye, Tee, Sockets, Reducers Hangers/supports/paint/making and repair of holes in slab/wall, excavation and back filling and as required for comp

Technical Specifications

Construction of Room for Filtration Plant and Drinking Water Area adjacent to AB-22.EFS 79806 — Excavation for foundations, in all kinds of soil (except conglomeration of gravel and boulders, soft, sandy or disintegrated and hard rock) and back filling the excavated material all-round the trenches including breaking clods, watering, consolidat

Specification
Excavation for foundations, in all kinds of soil (except conglomeration of gravel and boulders, soft, sandy or disintegrated and hard rock) and back filling the excavated material all-round the trenches including breaking clods, watering, consolidation by ramming in layers not exceeding 9 inches in depth to full compaction, dressing and disposal of surplus excavated stuff as directed, lead up to 200 feet and lift upto 5 feet. as directed by the Engineer Incharge.

Construction of Room for Filtration Plant and Drinking Water Area adjacent to AB-22.EFS 79806 — Providing and laying 4” thick 1:4:8 cement concrete using screened graded crushed stone 1/2" (13mm) and down gauge from approved source and lawrancepur sand as per specifications in foundation, under floor, under walk way including levelling, compact

Specification
Providing and laying 4” thick 1:4:8 cement concrete using screened graded crushed stone 1/2" (13mm) and down gauge from approved source and lawrancepur sand as per specifications in foundation, under floor, under walk way including levelling, compacting and curing etc. as directed by the Engineer Incharge.

Construction of Room for Filtration Plant and Drinking Water Area adjacent to AB-22.EFS 79806 — Providing and laying first class solid burnt brick masonry set in CSM (1:6) in straight or curved walls 9” to 18" thick including scaffolding, raking, out joints and curing etc; complete in foundation, as directed by the Engineer Incharge .

Specification
Providing and laying first class solid burnt brick masonry set in CSM (1:6) in straight or curved walls 9” to 18" thick including scaffolding, raking, out joints and curing etc; complete in foundation, as directed by the Engineer Incharge .

Construction of Room for Filtration Plant and Drinking Water Area adjacent to AB-22.EFS 79806 — Providing and laying 1:2:4 cement concrete hollow paving block masonry of 6”x8”x16” thick, set in CSM (1:4) in straight or curved walls including scaffolding, raking, out joints and curing etc; complete in ground floor, as directed by the Engineer In

Specification
Providing and laying 1:2:4 cement concrete hollow paving block masonry of 6”x8”x16” thick, set in CSM (1:4) in straight or curved walls including scaffolding, raking, out joints and curing etc; complete in ground floor, as directed by the Engineer Incharge .

Construction of Room for Filtration Plant and Drinking Water Area adjacent to AB-22.EFS 79806 — Providing and laying Precast Slab, including Precast Gurder , 3” thick P:C:C (1:2:4) screeding, leveling and curing, etc. complerte as directed by the Engineer Incharge.

Specification
Providing and laying Precast Slab, including Precast Gurder , 3” thick P:C:C (1:2:4) screeding, leveling and curing, etc. complerte as directed by the Engineer Incharge.

Construction of Room for Filtration Plant and Drinking Water Area adjacent to AB-22.EFS 79806 — Providing laying and applying 3mm thick roof grip water proofing PLASTO GRIP RLA-400 Modified bituminous membrane torch applied polymerized containing non-woven polyester coated, on lower side with PP modified bitumen compound with polyethylene film

Specification
Providing laying and applying 3mm thick roof grip water proofing PLASTO GRIP RLA-400 Modified bituminous membrane torch applied polymerized containing non-woven polyester coated, on lower side with PP modified bitumen compound with polyethylene film, on upper side PP modified bitumen compound with Aluminum Foil and applying roof-Grip primer @ 3to 4Sq. M per liter on RCC surface roof and unrolling, including overlap-age 10 cm at side and 15 cm at end; including the cost of removing, scraping existing membrane etc. from the roof surface, disposing of scraped material/debris and removing the dust by washing with water and removing the undulations and disposal, complete in all respect as per direction of engineer incharge. (Roof and Plinth Beam)

Construction of Room for Filtration Plant and Drinking Water Area adjacent to AB-22.EFS 79806 — Providing and applying cement sand (1:4) 1/2" thick plaster on internal/external walls and columns etc; in ground floor including making edges, corners and curing etc. as directed by the Engineer Incharge.

Specification
Providing and applying cement sand (1:4) 1/2" thick plaster on internal/external walls and columns etc; in ground floor including making edges, corners and curing etc. as directed by the Engineer Incharge.

Construction of Room for Filtration Plant and Drinking Water Area adjacent to AB-22.EFS 79806 — Providing and fixing of glazed Champagne anodized or powder coated aluminum openable ventilator as per British standard executive model section single glazed 101mmx37mm and 2mm thick including aluminum jali , the cost of fitting, with all accessories

Specification
Providing and fixing of glazed Champagne anodized or powder coated aluminum openable ventilator as per British standard executive model section single glazed 101mmx37mm and 2mm thick including aluminum jali , the cost of fitting, with all accessories cutting hole etc; and making good damages to walls etc; complete as required in ground floor as per direction of engineer-in-charge, including the cost of 5mm thick frosted glass.

Construction of Room for Filtration Plant and Drinking Water Area adjacent to AB-22.EFS 79806 — Providing and fixing, 12 mm thick glass door including fix glass also including floor machine, matching hardware, door handles, locking arrangements etc, complete as per direction of engineer incharge.

Specification
Providing and fixing, 12 mm thick glass door including fix glass also including floor machine, matching hardware, door handles, locking arrangements etc, complete as per direction of engineer incharge.

Construction of Room for Filtration Plant and Drinking Water Area adjacent to AB-22.EFS 79806 — Providing and fixing specific thickness full width Prepolished Granite Slab for top of drinking water area wall 3/4" thick for up to 12 Sft size, including grinding, polishing, making nose, cutting, etc complete as per direction of engineer incharge.

Specification
Providing and fixing specific thickness full width Prepolished Granite Slab for top of drinking water area wall 3/4" thick for up to 12 Sft size, including grinding, polishing, making nose, cutting, etc complete as per direction of engineer incharge.

Construction of Room for Filtration Plant and Drinking Water Area adjacent to AB-22.EFS 79806 — Providing and fixing, 16 SWG. Stainless Steel Drain Chanel (Tray), Size 1’ width, 6” deep including fixing arrangements, cutting, welding, Grinding, painting, nuts, bolts and washers etc, complete as per Drawing and direction of engineer incharge.

Specification
Providing and fixing, 16 SWG. Stainless Steel Drain Chanel (Tray), Size 1’ width, 6” deep including fixing arrangements, cutting, welding, Grinding, painting, nuts, bolts and washers etc, complete as per Drawing and direction of engineer incharge.

Construction of Room for Filtration Plant and Drinking Water Area adjacent to AB-22.EFS 79806 — Providing and installation of UPVC class-B drainage pipes including cost of all kinds of fittings such as Wye, Tee, Sockets, Reducers Hangers/supports/paint/making and repair of holes in slab/wall, excavation and back filling and as required for comp

Specification
Providing and installation of UPVC class-B drainage pipes including cost of all kinds of fittings such as Wye, Tee, Sockets, Reducers Hangers/supports/paint/making and repair of holes in slab/wall, excavation and back filling and as required for completion of works, Testing and commissioning. (Make Master Fit):3" dia