  • DEVELOPMENT/ CONSTRUCTION OF STRONG ROOM DOOR AT NBP 28,MALIR CANTT.,KARACHI WEST TICKET(115852)

Technical Specifications

DEVELOPMENT/ CONSTRUCTION OF STRONG ROOM DOOR AT NBP 28,MALIR CANTT.,KARACHI WEST TICKET(115852)

Specification
Dismantling an removing of existing masonry walls, False ceiling,fixtures, any other material etc. complete in all respects as per drawings. Job
Specification
Providing and laying R.C.C 1:1.5:3 as in strong room base, wall and slab (9" thick) using crushed stone fine sand and ordinary Portland Cenment including cost of labour and material complete in all respects as per drawings, specifications and as directed by the Consultant/Engineer.. Cft
Specification
Providing and fixing Deformed steel Gd-60 including bending, binding , cutting and placing in position, including chairs and wastage and labour cost complete in all respects as per drawings, specifications and as directed by the Consultant/Engineer.. Kg
Specification
Providing and laying plaster with cement sand mortar on brick and concrete surfaces as shown on drawing with G.I expanded metal at the joints etc complete in all respect a) 3/4" thick 1:6 Sft
Specification
Providing and applying Three coats of ICI Deluxe, Burger , Buxlays oil bonded distemper in approved colour at any floor height on ceiling, prepared to receive the paint after scraping, sand papering, prime coating and two coats of filling so Sft
Specification
Supply and installation i/c transportation of standard strong room / locker room door of size 7’ x 4’ x 11”, the main frame should be of 9mm thickness angle or U-channel and 6mm thickness main shutter a composite of outer 6mm and inner 3mm. The space between outer and inner sheet should be filled with fire proof material, tale and alum crystals. The outer 6mm plate is reinforced with 3mm thick anti-torch material plate in the locking regions. The lock area should be protected with 1/8x27x30 inch copper sheet. Thickness of door slab is 2”. Locking box wall made of wide 4” M.S sheet plate covered with 3mm BS sheet two brass locks with triple control locking system. Hinges made from 2-1/2” dia solid steel bars 9” in length & 12” long 4” wide flat bars with all bearings. Locking system triple control 2 way locking system. Made of 2.5” x 2.5” x 6mm angle iron 2-1/2” long 1-1/2” steel shooting bolts fixed on it with total no 11 bolts 6 at front & 5 at rear. Grill door, main frame and 08 Nos. supporting strips should be of ½” M.S Plates with 6/8” solid rounds bars 13-14 at brass locks with master control keys operation with grill door i/c exact alignment, plumb, welding. Placement of strong room door in vertical position in the opening of the strong room with chain kopi and welding of the the angle bars with steel bars of the strong room bars, complete in all respects as per drawings, specifications and as directed by the Consultant/Engineer. No