Skip to content

Opportunity overview

Active Federal PPRA / EPADS Official source

MAINTENANCE / REPAIR TO DAMAGE PILLAR AT ENTRANCE GATE OF KICT WEST WHARF

Civil Works Dept, KPT (Karachi Port Trust (KPT))

Reference: P188187

Tender information

Published
Submission deadline
Not specified
Procurement method
Request for Quotation
Procuring agency
Civil Works Dept, KPT (Karachi Port Trust (KPT))
Location
Karachi , Sindh

Tender description

  • MAINTENANCE / REPAIR TO DAMAGE PILLAR AT ENTRANCE GATE OF KICT WEST WHARF

Technical Specifications

MAINTENANCE / REPAIR TO DAMAGE PILLAR AT ENTRANCE GATE OF KICT WEST WHARF

Specification
(A-2) EXCAVATION FOR FOUNDATION, TRENCHES AND DRAINS TO THE REQUIRED, LEVELS, GRADE AND DRAINING ETC., IN ALL KINDS OF SOILS (EXCEPT GRAVELLY AND MOORUM SOIL, WET SILT, CLAY OR DISINTEGRATED SANDY AND HARD ROCK OR CONCRETE) AND BACK FILLING THE EXCAVATED MATERIAL IN FOUNDATION, PLINTH OR UNDER FLOOR INCLUDING BREAKING CLODS, WATERING, CONSOLIDATION BY RAMMING IN LAYERS NOT EXCEEDING 229MM (9") IN DEPTH TO FULL COMPACTION, DRESSING AND DISPOSAL OF USELESS EXCAVATED STUFF AND STACKING OF USEFUL MATERIAL AS PER DIRECTION OF ENGINEER IN CHARGE. PER/CUM
Specification
(B17) PROVDING AND LAYIIING 1:2:4 CEMENT CONCRETE USING CRUSHED GRADED BOULDERS (MACHINE BROKEN) OF SIZE 25MM (1")AND DOWN GAUGE IN FOUNDATION AND PLINTH INCLUDING SHUTTERING ,LEVELING COMPACTING AND CURING ETC.COMPLETE. PER/CUM
Specification
(E16) PROVIDING AND LAYING HARD GRADE RIBBED TOR STEEL (MINIMUM STRENGTH 60,000 PSI) REINFORCEMENT BARS WITH AND INCLUDING THE COST OF STRAIGHTENING, CUTTING, BENDING, BINDING, WASTAGE AND SUCH OVERLAPS AS ARE NOT SHOWN ON THE DRAWING PLACING IN POSITION IN CEMENT CONCRETE 1:2:4 PRECAST OR M.S. CHAIRS, TYING WITH BIND NG WIRE, COST OF CHAIRS AND WIRES ETC., IN ALL KIND OF RCC WORK IN FOUNDATION, BASEMENT, PLINTH AND GROUND FLOOR.. COMPLETE IN ALL RESPECT AS DIRECTED BY ENGINEER INCHARGE. PER/KG
Specification
(K-4) 19MM 3/4" THICK PLASTER 1:3 CEMENT MORTAR, FINISHED SMOOTH I/C CURING ETC COMPLETE.... PER/SQM
Specification
M/R OF IRON GATE LIKE AS CUTTING WELDING ,AND FIXING OF SAME TO SAME BASIS OR AS PER DIRECTION OF ENGINEER INCHARGE . EACH
Specification
(L-5) PREPARE SURFACE PROVDING COLOR AND APPLYING 2X COATS OF DISTEMPER APPROVED MAKE AND SHADE AND 1 COAT OF PRIMER INCLUDING SCRAPING SAND PAPERING DUSTING AND FILLING THE HOLES,CRACKS AND INEQUALITIES IF ANY AT ANY HEIGHT AND IN ANY FLOOR I/C. REMOVING RUBBISH ETC., OUTSIDE K.P.T. LIMIT COMPLETE WITH FINISHD SURFACE PER/SQM
Specification
(C13) (ADDITIONAL WORK AT WEST WHARF AREA.) PROVIDING AND LAYING 1:3:6 CEMENT CONCRETE SOLID BLOCK MASONRY OF SIZE 75MM TO 150MM (3" TO 6") THICK IN WALLS AND PILLARS USING GRADED SCREENED BAJRI 20MM (3/4") AND DOWN GAUGE SET IN 1:3 CEMENT MORTAR IN GROUND FLOOR SUPER STRUCTURES INCLUDING SCAFFOLDING RAKING OUT JOINTS AND CURING ETC., COMPLETE. PER/CUM
Specification
(K-3) PROVIDING AND APPLYING 13MM (1/2") THICK CEMENT SAND PLASTER, 1:4 CEMENT MORTAR, FINISHED SMOOTH I/C SCAFFOLDING, CURING ETC., OMPLETE. PER/SQM
Specification
(Z56) PREPARE SURFACE AND APPLYING 3 X COATS OF WEATHER SHIELD PAINT APPROVED MAKE AND SHADE INCLUDING M.S / WOODEN SCAFFOLDING OR AS DIRECTED BY ENGINEED INCHARGE SCRAPING SAND PAPERING DUSTING AND FILLING THE HOLES, CRACKS AND INEQUALITIES IF ANY AT ANY HEIGHT AND IN ANY FLOOR I/C. REMOVING RUBBISH ETC.. NOTE: (ITEMS INCLUDED RATE OF SCAFFOLDING AS MENTIONED) PER/SQM
Specification
LAYING AND FIXING OF DAMAGE PORTION OF PAVER BLOCK AT DIFFERENT LOCATION OF WEST WHARF PROPER FIXING KAKA, LEVELING ETC OR AS PER DIRECTION OF ENGINEER INCHARGE. PER/SQM
Specification
(B11) PROVDING AND LAYING 1:2:4 CEMENT CONCRETE USING CRUSHED GRADED BOULDERS (MACHINE BROKEN) OF SIZE 25MM (1")AND DOWN GAUGE IN FOUNDATION AND PLINTH INCLUDING SHUTTERING ,LEVELING COMPACTING AND CURING ETC.COMPLETE. PER/CUM
Specification
CONTINGENCIES @ 5% JOB
Specification
SRB @ 15% JOB
Specification

Official source

Always confirm dates, documents, and submission instructions on the originating portal.

View original tender on Federal PPRA / EPADS